3-phase track lighting
A 3-phase track lighting system is a professional lighting rail with three independently switchable circuits. Choose a 3-phase track when you want to control spotlights or pendant lights in up to three groups, for example in a store, showroom, office, or hospitality space.
Lengths, colors, and custom cutting
The 3-phase tracks are available in lengths of 100, 150, 200, and 300 centimeters and in white or black. You can also choose between a 3-phase surface-mounted track for ceiling mounting and a 3-phase recessed track for a flush finish.
Yes, the track can be cut to size. This allows you to adapt the lighting rail to the exact length of the space. When determining the measurements, take into account the space occupied by power connectors, couplers, and end caps.
Connecting and powering rails: how it works
You can connect multiple rails straight in a row or create an L-, T-, or X-shape. Every installation requires at least a power connector to connect the rail to the mains voltage and an end cap to safely seal the open end.
Connecting a 3-phase track starts with cutting the power to the installation. Then connect the phase, neutral, and earth to the power connector and check the position of the earthing and red marking at each connection. For the complete step-by-step guide, view the knowledge base article how to connect 3-phase tracklighting. If in doubt, have the electrical installation performed or checked by an electrician.
Which connectors do you need?
The correct connector is determined by the shape of the track system and the location of the power point.
| Desired connection | Required connector |
|---|---|
| Power supply at the start | Power connector Left or Right |
| Two rails in a straight line | I-shape connector |
| 90-degree angle | L-shape connector |
| Branch in three directions | T-shape connector |
| Intersection in four directions | X-shape connector |
| Power supply between two rails | I-middle power feed |
| Close open end | End cap |
Left and Right indicate on which side the red-marked conductor continues.This marking must be continued on the same side for power and corner connectors. If you choose the wrong direction, the circuit will be interrupted and the next rail section will not receive power.
With the 3-phase tracklighting configurator you can assemble rails, connectors, and accessories for your layout.
Spots and pendant lights on a 3-phase track
Only fixtures with a suitable 3-phase track adapter fit on a 3-phase track. With 3-phase tracksspots you can set phase L1, L2, or L3 per spot. Spots with the same phase setting are then switched or dimmed as a single group.
Yes, a pendant light can also be connected to a 3-phase track . For this, you need a suitable 3-phase pendant adapter that provides both the electrical connection and the mounting.Before installation, please check if the adapter is suitable for the weight and connection of the pendant light.
Frequently asked questions
How do I connect a 3-phase track?
Connect the track to the phase, neutral, and ground using a power feed connector, and check the red marking and grounding of all connectors before turning on the power. Always de-energize the system completely first and follow the step-by-step guide for connecting 3-phase trackphase lighting.
What does Left or Right mean for a power feed connector?
Left and Right indicate on which side the red-marked conductor of the track system is located. This position must be consistently maintained for all subsequent connectors; otherwise, the circuit will be interrupted and a subsequent track section will not receive power.
Can I cut a 3-phase track to size?
Yes, a 3-phase track can be cut to the required length. Measure the complete route including connectors beforehand and ensure the cut end is finished correctly before connecting the track.
Can I hang a pendant light from a 3-phase track ?
Yes, provided you use a suitable 3-phase pendant adapter. Be sure to check the electrical compatibility and the maximum permissible weight of the adapter; electrical power and mechanical load capacity are separate specifications.
How many spotlights can be placed on a single 3-phase track?
There is no fixed number of spotlights per track. The maximum is determined by the total wattage per phase and the permissible load of the track, connectors, switch, dimmer, and electrical group.Calculate this by dividing the lowest allowed wattage load by the power per spot. For example, a 150-watt dimmer can handle a maximum of ten 15-watt spots on the same phase.
View all 3-phase tracks — ordered before 16:00, delivered tomorrow.