Ordering for business? Take advantage of the benefits! Sign up as a premium business customer.

  • Free shipping on orders over 75,-

  • Ordered before 16:00 = delivered tomorrow

  • Pay later available

LED emergency lighting

Are you looking for reliable LED emergency lighting for an office, shop, warehouse, homeowners' association (VvE), or other commercial building? At LedLoket you will find escape route lighting, exit sign luminaires, and LED emergency luminaires with batteries in surface-mounted and recessed versions. This ensures that exits and walking routes remain visible, even if the mains power fails.

Check out these products as well

View as

Are you looking for reliable LED emergency lighting for an office, retail store, warehouse, homeowners association (VvE), or other commercial building? At LedLoket you will find escape route lighting, exit sign luminaires, and LED emergency luminaires with built-in batteries in both surface-mounted and recessed versions. This ensures that exits and walkways remain visible, even during a power outage.

Whether you want to buy emergency lighting immediately for a small space or are looking for a complete solution for a larger project: we are happy to help you choose the right luminaires, mounting method, and protection for your situation.

Which emergency lighting suits your situation?

LED emergency lighting serves two main functions: showing people where the exit is and providing sufficient light to evacuate safely. Which version you need depends on the space, the mounting type, and the desired operation in the event of a power failure.

Type Suitable for Important to note
Escape route lighting with pictogram Corridors, stairwells, exits, and intersections of escape routes Good visibility, correct arrow direction, wall or ceiling mounting
Emergency lighting fixture with battery Open spaces, workspaces, and routes where extra light is needed during a power failure Autonomy, light output, maintained or non-maintained operation
Outdoor emergency lighting IP65 External doors, galleries, porches, and damp or dusty areas IP rating, temperature environment, and robust housing

Escape route lighting and sign fixtures

Escape route lighting, also known as emergency exit signage, immediately clearly indicates where the nearest emergency exit is located.This type of fixture is used in locations where an exit, change of direction, or staircase must be clearly visible. Thanks to LED, the icon remains brightly illuminated with low energy consumption and a long lifespan.

Emergency fixtures with battery

An LED emergency light with a battery switches on automatically as soon as the normal power supply fails. This makes this type of fixture suitable as an emergency light in areas where people need to be able to orient themselves safely. Depending on the model, you can choose a standalone fixture with a built-in battery or a solution that fits within a central emergency lighting system.

Recessed or surface-mounted emergency lighting

Recessed emergency lighting is popular when you want a sleek finish, for example in suspended ceilings or representative spaces. Surface-mounted emergency lighting, on the other hand, is useful if you want quick installation or lack recessed space.Always pay attention to the cut-out size and installation depth for recessed fixtures, and to the sightline and mounting height for surface-mounted fixtures.

What should you look for when buying LED emergency lighting?

Autonomy, maintained operation, and self-test

Autonomy is the duration that the fixture remains illuminated without mains power. Many applications require a minimum operating time of 1 hour, while in other situations 3 hours may be required or mandated. Additionally, you choose between maintained emergency lighting, which is always on, and non-maintained emergency lighting, which only turns on during a power outage. Models with a self-test function make periodic inspections easier.

Light output and mounting position

Not every emergency lighting fixture needs to be equally bright. In corridors and escape routes, recognition and safe orientation are paramount, whereas open spaces often require greater light distribution.Therefore, do not only look at wattage, but primarily at the application, light distribution, and mounting position on a wall or ceiling. For exit sign luminaires, readability from a distance is also important.

IP rating for indoor and outdoor use

For dry indoor spaces, a standard version is often sufficient. In humid, cold, or dusty environments, it is better to choose emergency lighting with a higher IP rating, such as IP65. This is relevant for outdoor emergency lighting, as well as for technical rooms, warehouses, apartment entrances, and galleries.

Battery, maintenance, and replacement

Good emergency batteries are essential, because they ensure that the luminaire functions during a power outage. Batteries do not last forever and must be checked periodically. Especially in larger installations, it is smart to think ahead about testing convenience, maintenance, and potential future replacement.

Rules and standards at a glance

The exact requirements for emergency lighting depend on the building, its function, and the evacuation plan. However, a few standards are almost always relevant when selecting and managing a system. Would you like to review all the basic rules and selection guides in detail? Then read Everything about emergency lighting.

NEN-EN 1838

This standard describes the performance requirements for emergency lighting, such as the required illumination along escape routes and in high-risk areas. In practice, this means that a fixture must not only function during a power failure, but also provide sufficient light in the right place.

NEN-EN-ISO 7010 and NEN 3011

These standards cover pictograms and safety signs. The familiar green escape route pictograms and the direction of the arrows are standardized so that people can recognize the correct route without hesitation in an emergency situation.Therefore, it is important not only to choose an attractive fixture, but also the correct symbol.

NEN-EN 50172

NEN-EN 50172 focuses on the installation, management, inspection, and maintenance of emergency lighting systems. This is important for building owners and managers, because not only the purchase matters, but also periodic testing and documentation. Whether you are working on a new project or replacing an existing installation, consulting with an installer or advisor is recommended.

Buy LED emergency lighting at LedLoket

At LedLoket you benefit from a wide range of LED emergency lighting, competitive prices, and fast delivery from our own stock. We are happy to help you choose the right escape route lighting, a suitable surface-mounted or recessed emergency lighting fixture, or an IP65 solution for outdoor use.Are you working on a business project in Overijssel or anywhere else in the Netherlands? Then you can also count on personal technical advice, a free lighting calculation for larger requests, and support with a complete project quotation. Also check out our service page for Emergency lighting advice. You are also welcome in our showroom in Denekamp if you would like to compare products first.

Frequently asked questions about LED emergency lighting

What is the right emergency lighting during a power outage?

That depends on the room. For exits and escape routes, you generally choose escape route lighting with a pictogram. For open spaces or workspaces where extra visibility is needed, an emergency fixture with a battery is often the right choice.

What are the basic rules for emergency lighting?

Escape routes and emergency exits must be clearly identifiable, the lighting must function in the event of a power failure, and the system must be periodically tested and maintained. The exact version required depends on the application and the relevant standards.

What is the minimum operating time required for emergency lighting?

In many situations, a minimum autonomy of 1 hour is maintained. For certain buildings or types of use, 3 hours may be required or desirable. Therefore, always check the project requirements and the evacuation plan.

Does LED emergency lighting work without power?

Yes. A self-contained fixture automatically switches to the built-in battery during a power failure. In other systems, the emergency lighting can be powered from a central system.

Can LED be used in an old fixture with an emergency function?

Sometimes, but with emergency lighting, complete compatibility is extra important. Think of the battery, electronics, test function, and standards. In many cases, a completely new LED emergency lighting fixture is the most reliable and practical solution.

What is the difference between recessed and surface-mounted emergency lighting?

Recessed emergency lighting is concealed in the ceiling or wall and provides a sleek appearance. Surface-mounted emergency lighting is installed visibly on the surface and is often quicker to install during renovation or replacement.

What IP rating do I need for outdoor emergency lighting?

For outdoor use or in damp and dusty areas, a higher degree of protection, such as IP65, is often chosen. This provides better protection for the fixture against water and dirt compared to standard indoor models.

Frequently Asked Questions about Emergency Lighting

Is emergency lighting mandatory for my business?

In many cases, emergency lighting is legally required in public buildings, offices, healthcare facilities, and production environments. This depends on the size, use, and building regulations of the premises. For specific requirements, it is best to consult Dutch building regulations and NEN standards.

How often must emergency lighting be tested?

According to NEN-EN 50172, emergency lighting must be visually inspected monthly and undergo an annual duration test. This is to ensure that the lighting functions properly and is operational in emergencies.

What does an emergency lighting plan entail?

An emergency lighting plan is a design that describes the placement, type, and maintenance of emergency lighting in a building. The plan helps ensure effective and safe illumination of escape routes and takes the specific layout of the building into account.

What is the difference between centrally and decentrally powered emergency lighting?

  • Centralized emergency lighting Uses a central battery or emergency power supply for the entire building.
  • Locally powered emergency lighting Has its own battery per fixture. This type is often easier to install and can be more cost-effective, especially in smaller buildings.

Can I use LED lighting as emergency lighting?

Yes, LED lighting is suitable and even recommended for emergency lighting due to its energy efficiency and long lifespan. LED fixtures provide bright light and typically have lower maintenance costs than traditional lighting.

How does automatic emergency lighting work?

Automatic emergency lighting switches on when the power supply fails, thanks to a built-in battery or an external backup power system. This system ensures that the lighting immediately turns on to enable a safe evacuation.

How can I check if my emergency lighting is still working properly?

Much emergency lighting is equipped with an indicator light that shows whether the battery is charged. In addition, through regular testing, as recommended in the NEN-EN 50172 standard, you can check whether the lighting is still functioning properly.

Compare /4

Loading...